WAC 16-201-029
Secondary containment of liquid bulk
fertilizer -- Earthen walls. (1) Secondary containment walls
constructed of earth shall be allowed at permanent storage
facilities when a liner is used: Provided, That only permanent
storage facilities having storage containers of one hundred
thousand gallons or greater capacity can use clay liners.
(2) Earthen walls shall have a horizontal to vertical slope
of at least three to one, unless a steeper slope is consistent
with good engineering practice, and shall be packed and protected
from erosion.
(3) The top of earthen walls shall be no less than two feet
six inches wide.
[Statutory Authority: RCW 15.54.800. 00-23-075, § 16-201-029,
filed 11/17/00, effective 12/18/00.]