WAC 16-202-2005
What are the placement requirements for
application tanks? Application tanks cannot be located in an
area or placed in such a manner to contaminate water or to
endanger human health, sensitive areas, or the environment.
(1) Application tanks should be positioned downgradient from
wellheads, public waterways, off-farm irrigation supply ditches
or conveyance systems, or sensitive areas.
(a) If downgradient placement is not feasible, earthen berms
or other structures of sufficient design must be constructed to
divert spillage, leakage, or surface flow away from such areas.
(b) An application tank cannot be placed closer than twenty
feet from wellheads, public waterways, off-farm irrigation supply
ditches or conveyance systems, or sensitive areas.
(c) Mixing or loading activities cannot occur within twenty
feet of a sensitive area, wellhead, public waterway, off-farm
irrigation supply ditch or conveyance system, and irrigation
water source.
(d) Alternative technology that provides substantially equal
protection such as a secondary containment facility that complies
with the structural design requirements in the secondary and
operational area containment rules (chapter 16-201 WAC) will
fulfill the requirements in paragraphs (a), (b), and (c) of this
subsection.
(e) Overflow from an irrigation pond contaminated with
product cannot enter a public waterway, off-farm irrigation
supply ditch or conveyance system, or sensitive area.
(2) Application tanks must be positioned to prevent leaks,
spills, or structural damage.
(a) Application tanks must be placed on a rigid, sound
understructure or on stable ground to prevent tippage, spillage,
puncturing, or breakage.
(b) Application tanks and the injection system must be
protected against reasonably foreseeable risks of damage by
implements, trucks or other moving vehicles, or objects.
(3) Application tanks should be sited as close as reasonably
possible to the injection point.
(4) Tank outlet ports must be fitted with manual shutoff
valves.
[Statutory Authority: Chapters 15.54, 15.58, 17.21, and 34.05 RCW. 01-23-018, § 16-202-2005, filed 11/9/01, effective
11/9/01.]