WAC 173-160-371
What are the standards for chemical
conditioning? The use of detergents, chlorine, acids or other
chemicals in wells for the purpose of increasing or restoring
yield, shall be used according to manufacturer's
recommendations. Within a consolidated formation, the
placement or use of packers and subsequent pressurization
within the bore hole or casing while cleaning or
hydrofracturing shall not damage the seal at the drive shoe.
Except for disinfection and cleaning of wells, a well drilling
license is required for all other chemical conditioning that
alters the condition of the water well.