WAC 173-173-100
What are the specific requirements for
meters for pressure systems? (1) At any flow rate measured by
the meter, the meter itself shall be rated by the manufacturer to
register not less than ninety-five percent, nor more than one
hundred five percent, of the water actually passing through the
meter.
(2) At any flow rate measured by the measuring system; i.e.,
meter plus any secondary equipment such as data recorders; the
system shall register not less than ninety percent, nor more than
one hundred ten percent, of the water actually passing through
the system.
(3) The meter shall have a visual totalizer or the facility
shall be capable of totalizing the flow. The totalizer shall
contain sufficient recording digits to ensure that "roll over" to
zero does not occur before the next recording period.
(4) The department may require that the measuring device be
capable of indicating flow rate as well as totalized flow.
(5) For other conditions necessary to ensure accurate and
precise measurement data, the selection, installation and
maintenance of measuring devices by water users shall be guided
by generally accepted industry standards, such as the American
Water Works Association standards and information from the
manufacturer. These standards also shall be used by the
department in making decisions as to the appropriate selection,
installation, operation and maintenance of measuring devices
acceptable under this rule.
[Statutory Authority: RCW 90.03.360, 90.44.050, [90.44.]250,[90.44.]450
and chapter 43.21A RCW. 02-02-017 (Order 00-01), §
173-173-100, filed 12/21/01, effective 1/21/02.]