WAC 173-303-335
Construction quality assurance program. (1) CQA program.
(a) A construction quality assurance (CQA) program is
required for all surface impoundment, waste pile, and landfill
units that are required to comply with WAC 173-303-650 (2)(j)
and (k), 173-303-660 (2)(j) and (k), and 173-303-665 (2)(h)
and (j). The program must ensure that the constructed unit
meets or exceeds all design criteria and specifications in the
permit. The program must be developed and implemented under
the direction of a CQA officer who is a registered
professional engineer.
(b) The CQA program must address the following physical
components, where applicable:
(i) Foundations;
(ii) Dikes;
(iii) Low-permeability soil liners;
(iv) Geomembranes (flexible membrane liners);
(v) Leachate collection and removal systems and leak
detection systems; and
(vi) Final cover systems.
(2) Written CQA plan. The owner or operator of units
subject to the CQA program under (a) of this subsection must
develop and implement a written CQA plan. The plan must
identify steps that will be used to monitor and document the
quality of materials and the condition and manner of their
installation. The CQA plan must include:
(a) Identification of applicable units, and a description
of how they will be constructed.
(b) Identification of key personnel in the development
and implementation of the CQA plan, and CQA officer
qualifications.
(c) A description of inspection and sampling activities
for all unit components identified in subsection (1)(b) of
this section, including observations and tests that will be
used before, during, and after construction to ensure that the
construction materials and the installed unit components meet
the design specifications. The description must cover:
Sampling size and locations; frequency of testing; data
evaluation procedures; acceptance and rejection criteria for
construction materials; plans for implementing corrective
measures; and data or other information to be recorded and
retained in the operating record under WAC 173-303-380.
(3) Contents of program.
(a) The CQA program must include observations,
inspections, tests, and measurements sufficient to ensure:
(i) Structural stability and integrity of all components
of the unit identified in subsection (1)(b) of this section;
(ii) Proper construction of all components of the liners,
leachate collection and removal system, leak detection system,
and final cover system, according to permit specifications and
good engineering practices, and proper installation of all
components (e.g., pipes) according to design specifications;
(iii) Conformity of all materials used with design and
other material specifications under WAC 173-303-650,
173-303-660, and 173-303-665.
(b) The CQA program will include test fills for compacted
soil liners, using the same compaction methods as in the full
scale unit, to ensure that the liners are constructed to meet
the hydraulic conductivity requirements of WAC 173-303-650
(2)(j)(i)(B), 173-303-660 (2)(j)(i)(B), and 173-303-665
(2)(h)(i)(B) in the field. Compliance with the hydraulic
conductivity requirements must be verified by using in situ
testing on the constructed test fill. The department may
accept an alternative demonstration, in lieu of a test fill,
where data are sufficient to show that a constructed soil
liner will meet the hydraulic conductivity requirements of WAC 173-303-650 (2)(j)(i)(B), 173-303-660 (2)(j)(i)(B), and
173-303-665 (2)(h)(i)(B) in the field.
(4) Certification. Waste will not be received in a unit
subject to this section until the owner or operator has
submitted to the department by certified mail or hand delivery
a certification signed by the CQA officer that the approved
CQA plan has been successfully carried out and that the unit
meets the requirements of WAC 173-303-650 (2)(j) or (k),
173-303-660 (2)(j) or (k), or 173-303-665 (2)(h) or (j); and
the procedure in WAC 173-303-810 (14)(a) has been completed. Documentation supporting the CQA officer's certification must
be furnished to the department upon request.
[Statutory Authority: Chapters 70.105 and 70.105D RCW. 95-22-008 (Order 94-30), § 173-303-335, filed 10/19/95,
effective 11/19/95.]