WAC 173-400-060   Emission standards for general process units.  General process units are required to meet all applicable provisions of WAC 173-400-040 and, no person shall cause or allow the emission of particulate material from any general process operation in excess of 0.23 grams per dry cubic meter at standard conditions (0.1 grain/dscf) of exhaust gas. EPA test methods (in effect on February 20, 2001) from 40 CFR Parts 51, 60, 61, and 63 and any other approved test procedures which are contained in ecology's "Source Test Manual - Procedures For Compliance Testing" as of July 12, 1990, will be used to determine compliance.



[Statutory Authority: RCW 70.94.152. 05-03-033 (Order 03-07), § 173-400-060, filed 1/10/05, effective 2/10/05. Statutory Authority: Chapter 70.94 RCW, RCW 70.94.141,[70.94.]152 , [70.94.]331, [70.94.]510 and 43.21A.080. 01-17-062 (Order 99-06), § 173-400-060, filed 8/15/01, effective 9/15/01. Statutory Authority: [RCW 70.94.331, 70.94.510 and chapter 70.94 RCW.] 00-23-130 (Order 98-27), § 173-400-060, filed 11/22/00, effective 12/23/00. Statutory Authority: RCW 70.94.860, 70.94.510 and 70.94.331. 98-15-129 (Order 98-04), § 173-400-060, filed 7/21/98, effective 8/21/98. Statutory Authority: Chapter 70.94 RCW. 91-05-064 (Order 90-06), § 173-400-060, filed 2/19/91, effective 3/22/91. Statutory Authority: Chapters 43.21A and 70.94 RCW. 83-09-036 (Order DE 83-13), § 173-400-060, filed 4/15/83. Statutory Authority: RCW 70.94.331. 80-11-059 (Order DE 80-14), § 173-400-060, filed 8/20/80; Order DE 76-38, § 173-400-060, filed 12/21/76. Formerly WAC 18-04-060.]