| Dry cleaning facilities with: | Small area source purchases less than: | Large area source purchases between: | Major source purchases more than: | |
| (1) | Only Dry-to-Dry Machines | 140 gallons PCE/yr | 140-2,100 gallons PCE/yr | 2,100 gallons PCE/yr |
| (2) | Only Transfer Machines | 200 gallons PCE/yr | 200-1,800 gallons PCE/yr | 1,800 gallons PCE/yr |
| (3) | Both Dry-to-Dry and Transfer Machines | 140 gallons PCE/yr | 140-1,800 gallons PCE/yr | 1,800 gallons PCE/yr |
| Small area source | Large area source | Major source |
| Refrigerated condenser for all machines installed after September 21, 1993. | Refrigerated condenser for all machines. | Refrigerated condenser with a carbon adsorber for all machines installed after September 21, 1993. |
| Small area source | Large area source | Major source |
| Once every 2 weeks. | Once every week. | Once every week. |