WAC 246-272A-0130
Bacteriological reduction. This
section establishes the requirements for registering
bacteriological reduction processes.
(1) Manufacturers shall, for the purpose of product
registration as described in WAC 246-272A-0110 and 246-272A-0120 for meeting treatment levels A, B, or C, verify
bacteriological reduction performance by sampling for fecal
coliform.
(a) For products not yet tested according to ANSI/NSF
Standard 40 testing protocol dated July 1996 or later, the
requirements of both ANSI/NSF Standard 40 and the protocol
specified in subsection (2) of this section for verifying
bacteriological reduction must be met.
(b) For products that have been tested according to
ANSI/NSF Standard 40 dated July 1996 or later but have not yet
been tested for bacteriological reduction, treatment
performance of the treatment product or sequence may be
established based on test results for CBOD5 and TSS obtained
from the previous ANSI/NSF Standard 40 testing and
bacteriological reduction performance based on testing
according to the protocol in subsection (2) of this section.
Provided that the testing entity must verify the influent
wastewater stream throughout the bacteriological testing
period meets the influent threshold levels for CBOD5 and TSS
required by ANSI/NSF Standard 40 testing protocol.
(2) All test data submitted for product registration
shall be produced by an ANSI accredited, third-party testing
and certification organization whose accreditation is specific
to on-site wastewater treatment products. Bacteriological
reduction performance must be determined while the treatment
product or sequence is tested according to the ANSI/NSF
Standard 40 testing protocol. During this testing the
following requirements apply:
(a) Collect samples from both the influent and effluent
streams, identifying the treatment performance achieved by the
full treatment process (component or sequence);
(b) Obtain influent characteristics falling within a
range of 106 - 108 fecal coliform/100 mL calculated as
thirty-day geometric means during the test.
(c) Test the influent to any disinfection unit and report
the following at each occasion of sampling performed in (d) of
this subsection:
(i) Flow rate;
(ii) pH;
(iii) Temperature;
(iv) Turbidity; and
(v) Color.
(d) Obtain samples for fecal coliform analysis during
both the design loading and stress loading periods identified
by NSF Standard 40. Grab samples shall be collected from both
the influent and effluent on three separate days of the week.
Each set of influent and effluent grab samples must be taken
from a different dosing time frame (morning, afternoon, or
evening) so that samples have been taken from each dosing time
frame by the end of the week.
(e) Conduct analyses according to standard methods;
(f) Report the geometric mean of fecal coliform test
results from all samples taken within thirty-day or monthly
calendar periods;
(g) Report the individual results of all samples taken
throughout the test period design and stress loading; and
(h) Report all maintenance and servicing conducted during
the testing period, including for example, instances of
cleaning a UV lamp, or replenishment of chlorine chemicals.
(3) Manufacturers may register products in treatment
levels A and B using disinfection.
(4) Manufacturers may not register products for treatment
level C using disinfection.
[Statutory Authority: RCW 43.20.050. 06-01-020, §
246-272A-0130, filed 12/12/05, effective 1/12/06; 05-15-119, §
246-272A-0130, filed 7/18/05, effective 9/15/05.]