WAC 296-56-60117   Maintenance and load limits.  (1) The structural integrity of docks, piers, wharves, terminals and working surfaces shall be maintained.

     (2) Maximum safe load limits, in pounds per square foot (kilograms per square meter), of floors elevated above ground level, and pier structures over the water shall be conspicuously posted in all cargo areas.


Exception: Pier structures used primarily for vehicle traffic may be posted in maximum pounds per axle weight.

     (3) Maximum safe load limits shall not be exceeded.

     (4) All walking and working surfaces in the terminal area shall be maintained in good repair.

     (5) All steel plates, boards, etc., used to temporarily cover small holes or weakened surfaces shall be secured in such a manner as to prevent movement.

     (6) All large openings or weakened surfaces shall be barricaded on all exposed sides with barricades equipped with blinkers, flashing lights, or reflectors.

     (7) Areas around bitts or cleats where workers perform their duties shall be lighted as required in this section and have a nonslip surface around each bitt or cleat.



[Statutory Authority: RCW 49.17.040 and 49.17.050. 86-03-064 (Order 86-02), § 296-56-60117, filed 1/17/86; 85-10-004 (Order 85-09), § 296-56-60117, filed 4/19/85; 85-01-022 (Order 84-24), § 296-56-60117, filed 12/11/84.]