Dry kilns. (1) Dry kilns shall be so
constructed upon solid foundations that tracks will not sag. Dry kilns shall be provided with suitable walkways. Each kiln
shall have doors that operate from the inside and be provided
with escape doors of adequate height and width to accommodate
an average size man, that also operates from the inside, and
shall be located in or near the main door. Escape doors shall
swing in the direction of exit. Kiln doors and door carriers
shall be fitted with safety devices to prevent the doors or
carriers from falling.
(2) Ladders. A fixed ladder, in accordance with the
requirements of chapter 296-876 WAC, Ladders, portable and
fixed, or other means shall be provided to permit access to
the roof. Where controls and machinery are mounted on the
roof, a permanent stairway with standard handrail shall be
installed in accordance with the requirements of WAC 296-800-250.
(3) A heated room shall be provided for the use of the
kiln operator in inclement weather. He should remain in such
room for at least ten minutes after leaving a hot kiln before
going to cold outside air.
(4) Where operating pits are used, they shall be well
ventilated, drained and lighted. Substantial gratings shall
be installed at the kiln floor line. Steam lines shall be
provided with insulation wherever exposed to contact by
employees. Fans shall be enclosed by standard safeguards.
(5) Mechanical equipment. All belts, pulleys, blowers,
and other exposed moving equipment used in or about kilns
shall be guarded in accordance with chapter 296-806 WAC,
Machine safety.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050,
49.17.060. 06-16-020, § 296-78-71017, filed 7/24/06,
effective 12/1/06; 04-14-028, § 296-78-71017, filed 6/29/04,
effective 1/1/05. Statutory Authority: RCW 49.17.010,[49.17].040
, and [49.17].050. 01-11-038, § 296-78-71017,
filed 5/9/01, effective 9/1/01. Statutory Authority: Chapter 49.17 RCW. 96-17-056, § 296-78-71017, filed 8/20/96,
effective 10/15/96. Statutory Authority: RCW 49.17.040,
49.17.050 and 49.17.240. 81-18-029 (Order 81-21), §
296-78-71017, filed 8/27/81.]