WAC 296-150M-0302   What are some examples of work to manufactured or mobile homes that either require or do not require a permit and inspection?  


TYPE OF WORK ALTERATION PERMIT AND INSPECTION REQUIRED?

Yes No
(1) Air Conditioner/Heat Pump    
     (a) New installation X  
     (b) Replacement X  
     (c) Reconnection after moving home X  
     (d) Repair   X
     (e) Adjustment and/or maintenance   X
     
(2) Bottom Board - Repair   X
     
(3) Clothes Washer    
     (a) New installation   X
     (b) Replacement   X
     (c) Repair with approved parts   X
     (d) Adjustment and/or maintenance   X
     
(4) Clothes Dryer (Electric)    
     (a) New installation (Prewired electrical)   X
     (b) Replacement   X
     (c) Repair with approved parts   X
     (d) Adjustment and/or maintenance   X
     (e) Replacement with gas clothes dryer when modifications to electrical or gas systems are performed X  
     
(5) Clothes Dryer (Gas)    
     (a) New installation (Preplumbed gas)   X
     (b) Replacement   X
     (c) Repair with approved parts   X
     (d) Adjustment and/or maintenance   X
     (e) Replacement with electric clothes dryer when modifications to electrical or gas systems are performed X  
     
(6) Dishwasher    
     (a) New installation X  
     (b) Replacement    
          (i) Cord connected   X
          (ii) Direct wired X  
     (c) Repair   X
     (d) Adjustment and/or maintenance   X
     
(7) Doors (Interior and Exterior)    
     (a) Additional*      X  
     (b) Replacement of door that fits into the same opening   X
     
(8) Electrical    
     (a) Replacing main electrical panel****** X  
     (b) Adding circuits X  
     (c) Extending existing circuit(s) X  
     (d) Replacing lighting fixtures****   X
     (e) Replacing circuit breakers/fuses   X
     (f) Replacing switches, receptacles, light bulbs, fluorescent tubes and glass or plastic shades   X
     (g) Repairing bath exhaust fans   X
     (h) Repairing fans in kitchen range hoods   X
     
(9) Exterior Finish    
     (a) Painting   X
     (b) Replacement of siding X  
     
(10) Furnace (Electric)    
     (a) New installation X  
     (b) Replacement X  
     (c) Repair   X
     (d) Adjustment and/or maintenance   X
     (e) Replacement with gas furnace X  
     
(11) Furnace (Gas)    
     (a) New installation X  
     (b) Replacement X  
     (c) Repair   X
     (d) Change from LP Gas to Natural Gas or from Natural Gas to LP gas per its listing   X
     (e) Adjustment and/or maintenance   X
     (f) Replacement with electric furnace X  
     
(12) Gas Lines    
     (a) New installation X  
     (b) Extend existing gas line X  
     (c) Repair X  
     
(13) Interior    
     (a) Painting, wall papering and similar finish work   X
     (b) Replacement or addition of curtains, drapes, blinds, window shades and other window coverings   X
     (c) Replacement of carpeting and other floor-covering materials with similar materials   X
     
(14) Microwave Oven (Over range)    
     (a) New installation when electrical system modifications are performed X  
     (b) Replacement   X
     (c) Repair   X
     (d) Adjustment and/or maintenance   X
     
(15) Microwave Oven (Countertop)   X
     
(16) Pellet Stove    
     (a) New installation X  
     (b) Replacement X  
     (c) Repair   X
     (d) Adjustment and/or maintenance   X
     
(17) Plumbing    
     (a) Adding plumbing fixtures*** X  
     (b) Repairing damage*** X  
     (c) Replacing fixtures***   X
     (d) Repairing fixtures***   X
     (e) Replacement/repair of shower doors and curtains   X
     
(18) Range/Cook Top/Eye Level Oven (Electric)    
     (a) Replacement    
          (i) Cord connected   X
          (ii) Direct wired X  
     (b) Repair with approved parts   X
     (c) Adjustment and/or maintenance   X
     (d) Replacement with gas appliance(s) X  
     
(19) Range/Cook Top/Eye Level Oven (Gas)    
     (a) New installation X  
     (b) Replacement   X
     (c) Repair with approved parts   X
     (d) Adjustment and/or maintenance   X
     (e) Replacement with electric appliance(s) X  
     
(20) Roofing    
     (a) Reroofing X  
     (b) Applying liquid or mastic roof sealant to a metal roof   X
     (c) Repair of damaged composition shingles   X
     
(21) Structural changes    
     (a) Adding a dormer* X  
     (b) Truss repairs* X  
     (c) Add opening in wall** X  
     (d) Add gypsum board to walls or ceilings X  
     (e) Repair or replacing floor decking/joists X  
     
(22) Water Heater (Electric)    
     (a) Replacement w/electric water heater X  
     (b) Repair   X
     (c) Adjustment and/or maintenance   X
     (d) Replacement with gas water heater X  
     
(23) Water Heater (Gas)    
     (a) Replacement w/gas water heater X  
     (b) Repair   X
     (c) Change from LP gas to Natural Gas or from Natural Gas to LP gas per its listing   X
     (d) Adjustment and/or maintenance   X
     (e) Replacement with electric water heater X  
     
(24) Windows    
     (a) Replacement in same opening with no structural changes*****   X
     (b) Replacement when structural changes are required X  
     (c) Replacement of glass   X
     
(25) Wood Stove/Fireplace    
     (a) New installation X  
     (b) Replacement X  
     (c) Repair   X
     (d) Adjustment and/or maintenance   X

     * May also require a plan review. Please contact your local L&I representative.

     ** May also require a plan review. The department has detailed drawings you may use for openings in sidewalls. Please contact your local L&I representative.

     *** Fixtures include: Faucets, sinks, lavatories, laundry tubs, water closets (toilets), tubs, showers and tub/shower combos.

     **** Fixtures must be installed per its listing and intended use.

     ***** Windows in bedrooms must be of egress type.

     ****** Meter bases may only be installed by the manufacturer of the home unless repaired or replaced.

     NOTE: Exemption from the permit and inspection requirements shall not be deemed to grant authorization for any work to be done in violation of the applicable code, Chapter 296-150M WAC.



[Statutory Authority: Chapter 43.22 RCW and 2005 c 399. 05-24-020, § 296-150M-0302, filed 11/29/05, effective 1/1/06. Statutory Authority: Chapter 43.22 RCW and 2003 c 291. 05-01-102, § 296-150M-0302, filed 12/14/04, effective 2/1/05. Statutory Authority: RCW 43.22.340, 43.22.400, 43.22.432, 43.22.433, 43.22.434, 43.22.480, and 43.22.485, 2002 c 268, and chapter 43.22 RCW. 03-12-044, § 296-150M-0302, filed 5/30/03, effective 5/30/03. Statutory Authority: RCW 43.22.340, 43.22.350, 43.22.432, 43.22.434, 43.22.440, and 2001 c 335. 02-03-048, § 296-150M-0302, filed 1/9/02, effective 1/9/02.]