WAC 480-75-370
Design factor (F) for steel pipe. Except
as otherwise provided in subsections (1), (2) and (3) of this
section, the design factor a pipeline company used in the
design formula in 49 CFR Section 195.106 for new pipelines is
determined in accordance with the following table. The
applicable version of the Code of Federal Regulations and how
to obtain it is set out in WAC 480-75-999, Adoption by
reference.| Class location |
Design factor (F) |
| 1 |
0.72 |
| 2 |
0.60 |
| 3 |
0.50 |
| 4 |
0.40 |
(1) For Class 1 locations a design factor of 0.60 or less
must be used in the design formula in 49 CFR Section 195.106
for steel pipe in Class 1 locations that:
(a) Crosses the right of way of an unimproved public
road, without a casing;
(b) Crosses without a casing, or makes a parallel
encroachment on the right of way of either a hard-surfaced
road, a highway, a public street, or a railroad;
(c) Is supported by a vehicular, pedestrian, railroad, or
pipeline bridge; or
(d) Is used in a fabricated assembly (including mainline
valve assemblies, cross-connections, and river crossing
headers).
(2) For Class 2 locations, a design factor of 0.50, or
less, must be used in the design formula in 49 CFR Section
195.106 for uncased steel pipe that crosses the right of way
of a hard-surfaced road, a highway, a public street, or a
railroad.
(3) For Class 1 and Class 2 locations, a design factor of
0.50, or less, must be used in the design formula in 49 CFR
Section 195.106 for:
(a) Steel pipe in a pump station; and
(b) Steel pipe (including a pipe riser, on a platform
located offshore or in inland navigable waters).
[Statutory Authority: RCW 80.01.040, 80.04.060, 81.88.040. 08-12-045 (Docket PL-070974, General Order R-548), §
480-75-370, filed 5/30/08, effective 6/30/08. Statutory
Authority: RCW 80.01.040 and 80.04.160. 02-18-032 (Docket
No. TO-000712, General Order No. R-500), § 480-75-370, filed
8/26/02, effective 9/26/02.]